Article ID Journal Published Year Pages File Type
6740669 Engineering Structures 2015 12 Pages PDF
Abstract
Two approximately half-scale four-story coupled shear wall specimens were tested under both gravity and lateral displacement reversals. Specimen CW-RC, featuring traditional reinforced concrete (RC) shear walls and RC coupling beams, sustained ductile hysteretic response up to 3.00% drift. Specimen CW-S, featuring RC shear walls and steel coupling beam with low yield point steel (LYP) web, failed after completion of 2.00% drift cycles. The proposed connection detailing between the steel coupling beam and RC shear wall worked well in Specimen CW-S. Research results indicate that a ductile coupling beam design does not guarantee a ductile behavior of a coupled shear wall system. RC shear walls should be proportioned for axial and shear based on the provided coupling beam capacities. Design recommendations are provided.
Related Topics
Physical Sciences and Engineering Earth and Planetary Sciences Geotechnical Engineering and Engineering Geology
Authors
, , ,