Article ID | Journal | Published Year | Pages | File Type |
---|---|---|---|---|
6741332 | Engineering Structures | 2013 | 9 Pages |
Abstract
Using experimental results, the validity of Expressions 7.19 and 7.9 of Eurocode 2 (EC2) are examined. The additional damage within the tension zone caused by the repeated load types is not accounted for in either expression, meaning that the tension stiffening effect is overestimated. Consequences of this are that design code SLS (serviceability limit state) checks for beams with complex load histories may be inaccurate, and that the average steel stress within the reinforced concrete sections may be underestimated.
Related Topics
Physical Sciences and Engineering
Earth and Planetary Sciences
Geotechnical Engineering and Engineering Geology
Authors
Lee Higgins, John P. Forth, Anne Neville, Rod Jones, Trevor Hodgson,