Article ID | Journal | Published Year | Pages | File Type |
---|---|---|---|---|
6741780 | Fire Safety Journal | 2018 | 12 Pages |
Abstract
Numerical results show a good agreement with the experimental ones, so ANSYS and the described methodology prove to be good tools to simulate the performance of timber dovetail connections under a fire event. Traditional failure criteria, which are useful at room temperature, such as Tsai-Wu one, are used in the simulation in order to predict the failure time, but it was demonstrated that this failure criterion is useless at high temperatures, as the ones reached under a 30-min fire event.
Keywords
Related Topics
Physical Sciences and Engineering
Engineering
Civil and Structural Engineering
Authors
Rubén Regueira, Manuel Guaita,