Fusion-fission hybrid reactor takes advantage of the best of both domains, fusion and fission, without needing a full development of fusion reactor, and without critical safety issues of fission reactor. However, decay heat still exists in fission blanket of hybrid rector in shutdown state, which will menace the safety of rector if it cannot be smoothly carried out. To testify the passive safety characteristics of fission blanket, the reactor coolant pump shaft seizure accident in fission blanket of FFHER, a fusion-fission hybrid reactor, is simulated. The model of passive residual heat removal system, as well as reactor coolant system, are built using software SCDAP/RELAP5 4.0. The analysis shows that the simulated system response is reasonable. In the SG domination stage, the peak fuel temperature keeps always below the limiting value. In the PRHR domination stage, three cases are simulated and compared to choose appropriate parameter. It is found that PRHR circulation can be rapidly established and transfer enough heat from blanket. The transition from SG domination to PRHR domination is smooth. From the simulation results, it can be concluded that PRHRS can provide sufficient blanket cooling capability in LOFA.