Article ID Journal Published Year Pages File Type
6746097 Fusion Engineering and Design 2015 5 Pages PDF
Abstract
3D thermal analysis of PFC using ANSYS has been carried out to ensure its thermal stability. The cooling parameters have been calculated according to average incident flux on divertors and passive stabilizers. Engineering design demonstrated the required mass flow rate and velocity for cooling water in each sub-connection are optimized to be 0.43 kg/s and 5.5 m/s for efficient heat extraction under steady state heat load. Maximum temperature which PFC could be maintained is 355 °C and is well within threshold limits of material property degradation. The header distribution, modeled using AFT fathom, resulted for required parameters within maximum 5% of deviation.
Related Topics
Physical Sciences and Engineering Energy Energy Engineering and Power Technology
Authors
, , ,