Abstract
⺠We review the mechanical and electrical requirements on the ITER CC. ⺠He inlets are being developed to keep weld quality while minimizing temperature during welding. ⺠Prototype terminal joints with resistance in the range of 1-2 nΩ have been manufactured. ⺠An insulation mock-up sustained 50 kV for ground insulation without breakdown. ⺠Models of CC cases have been manufactured and welding development is ongoing.
Keywords
Related Topics
Physical Sciences and Engineering
Energy
Energy Engineering and Power Technology
Authors
P. Libeyre, C. Cormany, N. Dolgetta, N. Mitchell, H. Li, W. Wu, S. Du, S. Han, L. Liu, Li Wang, Lin Wang, J. Wei, X. Yu, Z. Zhou, A. Nijhuis, S. Sgobba,