Article ID Journal Published Year Pages File Type
6758151 Marine Structures 2013 12 Pages PDF
Abstract
The tolerances of steel sheet thicknesses - usually in the order of ±6% - are often neglected when investigating the remaining thickness in steel sheet piles. A simple calculation model shows that the sheet pile must be almost 50 years of age before an accurate estimation on the corrosion rate can be made, considering the tolerances, if the true original sheet pile thickness is not known.
Related Topics
Physical Sciences and Engineering Engineering Civil and Structural Engineering