Article ID Journal Published Year Pages File Type
6758226 NDT & E International 2018 34 Pages PDF
Abstract
Alternating current field measurement (ACFM) is an electromagnetic inspection method. It can be used as an alternative to magnetic particle inspection in the pipeline industry. This paper presents an ACFM probe for efficient, accurate, and contactless inner inspection of pipelines. The performance of the detection elements, cambered rectangular current-carrying coil, and cambered rectangular core are simulated, and the influences of various parameters, lift-off value, and inducing frequency are optimised. Finally, experiments are carried out using the proposed probe to evaluate its detective ability. The smallest axial crack detected by the probe had a length of 3 mm and depth of 1 mm. The results of this study show that the probe can quantitatively evaluate axial cracks on the surface of a pipeline, and the findings will aid in designing ACFM probe.
Related Topics
Physical Sciences and Engineering Engineering Civil and Structural Engineering
Authors
, , ,