Article ID Journal Published Year Pages File Type
6758277 NDT & E International 2018 22 Pages PDF
Abstract
The speed of vertical electrical impedance testing of a concrete bridge deck using a new rolling probe was demonstrated in this research to be 190 m2/h, which is more than six times faster than the speed at which data were collected using the static probe utilized in earlier research. Furthermore, with impedance measurements obtained at a longitudinal spacing of approximately 0.1 m, the spatial resolution was 12 times greater than that of the static probe. Vertical electrical impedance testing was performed together with half-cell potential testing, chaining, cover depth, and chloride concentration testing, and an interpretation of these data sets was developed that synergistically incorporated the deck maintenance history.
Related Topics
Physical Sciences and Engineering Engineering Civil and Structural Engineering
Authors
, , ,