Article ID Journal Published Year Pages File Type
6758495 NDT & E International 2013 7 Pages PDF
Abstract
The amplitude of an ultrasonic signal generated by electromagnetic acoustic transducers (EMATs) is typically low when compared to those generated by contacting transducers, which restricts the application of EMATs in the fields of nondestructive testing and nondestructive evaluation. The transmission process of a surface wave EMAT is studied, based on a previously established 3-D model, with the aim of enhancing the amplitude of ultrasonic waves generated by the EMAT. The effect of changing various EMAT parameters on the surface wave is investigated, by utilizing the orthogonal test method. Results indicate that after optimization, the signal amplitude of the EMAT has increased by 25.2%.
Related Topics
Physical Sciences and Engineering Engineering Civil and Structural Engineering
Authors
, , , ,