Abstract
At last, the Loss of Coolant Accidents (LOCAs) with a small break size and a large break size occurring at the main coolant line of Chinese Super-Critical Water-cooled Reactor (CSR1000) are simulated. The results show that CSR1000 with its official safety system design can be cooled down during the considered accidents and code TACOS has good feasibility for safety analysis of supercritical water systems.