Abstract
The PHX stability analysis is initially performed on the original tube bundle without the adoption of any stabilizing devices, in order to check the natural behavior of the system. The possible adoption and design of an orifice is then conducted on the basis of this preliminary study. The system response against the various types of instabilities, before the introduction of an orifice, is not completely satisfactory: a stable flow is found within certain specific system parameters ranges. After the introduction of a suitable orifice, the system behavior becomes stable under all operating conditions against all types of two-phase flow instabilities.