Article ID | Journal | Published Year | Pages | File Type |
---|---|---|---|---|
6760036 | Nuclear Engineering and Design | 2016 | 9 Pages |
Abstract
The helium flow measurement method is very important for the design of HTR-PM. Water experiments and numerical simulation with a 1/5 scaled model are conducted to investigate the flow measurement method utilized in the steam generator of HTR-PM. Pressure information at specific location of the 90° elbows with the diameter of 46.75 mm and radius ratio of 1.5 is measured to evaluate the flow rate in the riser-pipes. Pressure uniformity at the bottom of the experimental apparatus is tested to evaluate the influence of the equipment error on the final experimental results. Numerical results obtained by using the realizable k-ε model are compared with the experimental data. The results reveal that flow oscillation does not occur in the confluence system. For every single riser-pipe, the flow is stable despite the nonuniformity of the flow distribution. The average flow rates of the two pipe series show good repeatability regardless of the increases and decreases of the average velocity. In the header box, the flows out of the riser-pipes encounter with each other and finally distort the pressure distribution and the nonuniformity of the flow distribution becomes more significant along with the increasing Reynolds number.
Related Topics
Physical Sciences and Engineering
Energy
Energy Engineering and Power Technology
Authors
Shiming Wang, Cheng Ren, Yangfei Sun, Jiyuan Tu, Xingtuan Yang,