Article ID Journal Published Year Pages File Type
6761227 Nuclear Engineering and Design 2015 10 Pages PDF
Abstract
The Results of tensile and crack extension testing conducted on irradiated austenitic overlay cladding material are presented. The specimens were machined from three trepans sampled from the decommissioned WWER-440/V-230 reactor pressure vessel of the nuclear power plant Greifswald Unit 4. Crack extension curves were measured with Charpy size SE(B) specimens using the unloading compliance technique according to ASTM E1820-11 at different temperatures. Provisional crack initiation fracture toughness values JQ and KJQ are determined. The highest KJQ values were found in the temperature range from 20 to 80 °C. A significant scatter was observed in the initiation values. This is due to the inhomogeneous structure of the welded overlay cladding. During the loading the crack moves through regions with different tearing strength, thus the J-Δa values show discontinuities caused by fast crack propagation or crack jumps. The comparison of the measured KJQ values and conservatively estimated stress intensity factors at an assumed surface crack shows that the cladding would remain intact during pressurized thermal shock transient.
Related Topics
Physical Sciences and Engineering Energy Energy Engineering and Power Technology
Authors
, , ,