Abstract
This paper primarily deals with the design, development and testing of Accumulator Isolation Passive Valves (AIPV) proposed to be used in the ECCS. A 25Â NB size AIPV has been designed and successfully tested at Integral Test Loop (ITL) under simulated reactor conditions. It is a self-acting, ANSI 600 rating valve, which requires no external energy (i.e., neither air nor electrical power). It not only provides passive isolation but also passively controls high pressure liquid discharge through it. The design concept of the valve, functional performance, in situ valve testing methodology and the test results at simulated conditions are discussed.