Performance of a collector in solar dryer, equipped with porous and recycling system was investigated at three airflow rates (0.009, 0.018 and 0.036â¯kg/s). The CFD model was applied for developing the thermal response simulation of the collector for outlet air temperature, energy and exergy parameters. The predicted and experimental data were analyzed. The results illustrated a quit good correlation between the predicted data by CFD model and experimental data. The maximum energy and exergy efficiencies were 63.4% and 22.3%, respectively, for mass flow rate of 0.009â¯kg/s. In general, porous and recycling system not only improved the thermal efficiency of the dryer, but also accelerated the drying time. The energy and exergy efficiencies of the collector with porous and recycling system were about 19.1% and 19.5%, respectively higher than the energy and exergy of the collector without them. The maximum total thermal energy of the collector (21.24â¯MJ) was produced at the airflow rate of 0.009â¯kg/s. No adverse effect was found on the quality of the dried products with employing of porous and recycling system in solar dryer.
Related Topics
Physical Sciences and Engineering
Energy
Renewable Energy, Sustainability and the Environment
Authors
Akbar Arabhosseini, Hadi Samimi-Akhijahani, Mehrnosh Motehayyer,