Abstract
In the current study, a thermoeconomic analysis of two different solar hot water systems based on two types of flat plate collector (FPC) and evacuated tube collector (ETC) are studied under the cold climate conditions of Iran. The annual solar collector energy output and the collectors' output temperature are calculated using the TRNSYS16 software. As a result, it is found that the inlet temperature and weather conditions are the two major variables which affect the collector performance. Finally, according to the thermal and economic analysis, the performance of ETC system is 41% better than FPC system, and the yearly useful energy gain of ETC is 30% more than that of FPC in cold climate. So, applying ETC in cold climate is recommended. Additionally, this simulation will be extendable and applicable for every zone with any climatic condition.
Related Topics
Physical Sciences and Engineering
Energy
Renewable Energy, Sustainability and the Environment
Authors
Tahmineh Sokhansefat, Alibakhsh Kasaeian, Kiana Rahmani, Ameneh Haji Heidari, Faezeh Aghakhani, Omid Mahian,