Article ID | Journal | Published Year | Pages | File Type |
---|---|---|---|---|
6765840 | Renewable Energy | 2016 | 14 Pages |
Abstract
The thermal analysis of a Room (R) coupled with a Double Glazing Window (DGW) with/without solar control film (SCF) for warm and cold climate conditions of Mexico City is presented. The right vertical surface of the room is considered partially adiabatic and with a DGW. The DGW consists of two vertical semitransparent walls: glazing-1 facing the room, and glazing-2 facing the external environment; there is a SCF attached to glazing-1 for cold climate condition, or glazing-2 for warm climate condition. During one day, the hourly simulations of the R-DGW were done in an in-house code based on the finite volume method. To carry out the thermal analysis of the R-DGW, three cases were defined: Case C1 corresponds to the R-DGW without SCF; Case C2 and C3 correspond to the R-DGW with SCF for warm and cold climate condition, respectively. For warm climate condition the use of a SCF is highly recommended, since Case 2 reduces the amount of energy gained in â67.7% compared to Case 1. When using the SCF on the R-DGW for cold climate condition case C3, the average temperature inside of the room is similar to case C1.
Keywords
Related Topics
Physical Sciences and Engineering
Energy
Renewable Energy, Sustainability and the Environment
Authors
J. Xamán, Y. Olazo-Gómez, Y. Chávez, J.F. Hinojosa, I. Hernández-Pérez, I. Hernández-López, I. Zavala-Guillén,