Article ID | Journal | Published Year | Pages | File Type |
---|---|---|---|---|
693767 | Progress in Organic Coatings | 2009 | 7 Pages |
Abstract
Corrosion electrochemical behavior of chlorinated rubber top coating (single-layer), inorganic zinc-rich primer/chlorinated rubber top coating (double-layers) and inorganic zinc-rich primer/epoxy middle paste/chlorinated rubber top coating (tri-layers) in 3.5Â wt% NaCl solution was studied by electrochemical impedance spectroscopy (EIS). A series of impedance spectra of the three coating systems during immersion were measured; and their protective properties were compared according to the spectra. The experimental results showed that, the protective properties of the double-layers coating system were even worse than that of the single-layer coating system; and the tri-layers coating system had the best protective properties in the three coating systems; epoxy middle paste had played a very important role for protective properties of the composite coating system.
Related Topics
Physical Sciences and Engineering
Chemical Engineering
Process Chemistry and Technology
Authors
Xuwen Liu, Jinping Xiong, Yongwu Lv, Yu Zuo,