| Article ID | Journal | Published Year | Pages | File Type | 
|---|---|---|---|---|
| 6972841 | Journal of Loss Prevention in the Process Industries | 2018 | 7 Pages | 
Abstract
												The relationship between the explosion inerting effectiveness of rock dusts on coal dusts, as a function of the specific surface area (cm2/g) of each component is examined through the use of 20-L explosion chamber testing. More specifically, a linear relationship is demonstrated for the rock dust to coal dust (or incombustible to combustible) content of such inerted mixtures with the specific surface area of the coal and the inverse of that area of the rock dust. Hence, the inerting effectiveness, defined as above, is more generally linearly dependent on the ratio of the two surface areas. The focus on specific surface areas, particularly of the rock dust, provide supporting data for minimum surface area requirements in addition to the 70% less than 200 mesh requirement specified in 30 CFR 75.2.
											Related Topics
												
													Physical Sciences and Engineering
													Chemical Engineering
													Chemical Health and Safety
												
											Authors
												Isaac A. Zlochower, Michael J. Sapko, Inoka E. Perera, Connor B. Brown, Marcia L. Harris, Naseem S. Rayyan, 
											