Abstract
For the first time, new explosion regions were identified for diluted methane-coal dust cloud mixtures when using 1, 5 and 10 kJ ignitors. Finally, the Le-Chatelier mixing rule was modified to predict the lower explosion limit of methane-coal dust cloud hybrid mixtures considering the energy of the ignitors.
Related Topics
Physical Sciences and Engineering Chemical Engineering Chemical Health and Safety