Article ID Journal Published Year Pages File Type
697418 Automatica 2010 13 Pages PDF
Abstract

Hierarchical Interface-Based Supervisory Control employs interfaces that allow properties of a monolithic system to be verified through local analysis. By avoiding the need to verify properties globally, significant computational savings can be achieved. In this paper we provide local requirements for a multi-level architecture employing command-pair type interfaces. This multi-level architecture allows for a greater reduction in complexity and improved reconfigurability over the two-level case that has been previously studied since it allows the global system to be partitioned into smaller modules. This paper also provides results for synthesizing supervisors in the multi-level architecture that are locally maximally permissive with respect to a given specification and set of interfaces.

Related Topics
Physical Sciences and Engineering Engineering Control and Systems Engineering
Authors
, , , , ,