Article ID Journal Published Year Pages File Type
6974261 Process Safety and Environmental Protection 2018 13 Pages PDF
Abstract
The model has been validated against experimental data available in the literature and then applied to a number of reference cases, to assess the influence of the main parameters involved in the phenomenon on the evolution of the accident. This approach can be very helpful in various applications, such as risk analysis, where a large number of different scenarios must be simulated and/or the most critical conditions must be quickly identified. It has been found that the temperature of the tank wall in contact with the vapour phase is the most critical parameter. The time-to-failure of the tank is mainly affected by the received heat flux, while the time for the first opening of the pressure relief valve is very sensitive to both the initial storage temperature conditions and the heat input.
Related Topics
Physical Sciences and Engineering Chemical Engineering Chemical Health and Safety
Authors
, ,