Abstract
This study compares Hot Wire Tungsten Inert Gas Stellite 6 weld cladding on a low carbon steel substrate with a lost wax cast Stellite 6 in impingement erosion-corrosion conditions. Austenitic stainless steel samples were used as a reference material. Tests were conducted in a closed loop impinged slurry vessel with a jet velocity of 18â¯m/s with 3.5%NaCl aqueous solution containing 500â¯Âµm spherical silica sand particles (0.5â¯g/l sand concentration). The testing temperature was 40â¯Â°C. Mass loss measurements and a volumetric analysis as well as microstructural evaluation were used as post-test analysis techniques. Results showed that weld cladding and lost wax cast Stellite 6 performed better than the stainless steel, with the weld cladding marginally outperforming the lost wax cast technique.
Related Topics
Physical Sciences and Engineering
Chemical Engineering
Colloid and Surface Chemistry
Authors
F. Brownlie, C. Anene, T. Hodgkiess, A. Pearson, A.M. Galloway,