Article ID Journal Published Year Pages File Type
7008035 Desalination 2018 7 Pages PDF
Abstract
Membrane induction times in the flow systems increased linearly with the increase of flow Reynolds (Re) number from 80 to 6800 both without and with AS. The induction period in the presence of the AS was higher than that observed in AS free solutions. However, the extension of the induction period induced by the AS increased markedly with the Re number. Comparison of induction times measured in membranes and stirred beaker systems revealed a critical Re number below which induction time was shorter in the membrane system and above which the induction time was longer in the membrane system compared to the beaker test.
Related Topics
Physical Sciences and Engineering Chemical Engineering Filtration and Separation
Authors
, , ,