7020945 Journal of Membrane Science 2015 46 Pages PDF
Abstract
Higher porosities (or equivalently smaller effective membrane thickness), leading to higher water permeabilities, are also obtained for more loaded membranes. Too high SWCNT contents lead to a saturation and decrease of removal probably because high porosities lead to a decrease in adsorption due to both a decrease in the available surface and a clearing out due to convection through the membrane.