Article ID Journal Published Year Pages File Type
703948 Electric Power Systems Research 2012 10 Pages PDF
Abstract

Energy efficiency improvement for pumping system is an important problem for industrial energy systems. This article aims to improve pump efficiency by an approach based on energy efficiency classifications. To this purpose, an optimal pump sizing model is presented for new pumping system design, and an optimal pump operational control model is also given for existing pumping systems to minimize energy consumption cost and improve energy efficiency. Closed-loop model predictive control strategy is further applied for the pump operational control. These models show that the energy efficiency classification in terms of system performance, operation, equipment and technology (POET) is applicable to the pumping system energy efficiency study. Examples are given to illustrate the proposed models, which also convince the applicability of POET energy efficiency classification in the pumping system study.

Related Topics
Physical Sciences and Engineering Energy Energy Engineering and Power Technology
Authors
, , ,