Article ID Journal Published Year Pages File Type
7052039 Experimental Thermal and Fluid Science 2016 25 Pages PDF
Abstract
In this work the thermal performance of hybrid and single type nanofluid is investigated in a coiled heat exchanger at constant wall temperature and laminar flow operating conditions. The nanoparticle concentration is in the range of 0.1-0.4 vol% and the composition of the synthesized nanoparticle regarding hybrid nanofluid experiments is 97.5% alumina and 2.5% Ag. The maximum rate of heat transfer can be obtained by using the hybrid nanofluid at a concentration of 0.4 vol% which is 31.58% higher than that of the distilled water. Overall, the maximum thermal performance factor for hybrid nanofluid is about 2.55 suggesting the superior performance of the presented approach for energy intensification in heat exchangers.
Related Topics
Physical Sciences and Engineering Chemical Engineering Fluid Flow and Transfer Processes
Authors
, , ,