Article ID | Journal | Published Year | Pages | File Type |
---|---|---|---|---|
7052467 | Experimental Thermal and Fluid Science | 2014 | 6 Pages |
Abstract
This work presents measurements of the contact angle of sessile droplets for three nanofluids, i.e. water-Al2O3, water-TiO2 and water-Cu. The plates made of glass, anodized aluminium and stainless steel of different roughness served as substrates. Ultrasonic vibration was used for 30-60Â min in order to stabilise the dispersion of the nanoparticles. Nanoparticles were tested at the concentration of 0.01%, 0.1%, and 1% by weight. Three methods of contact angle measurement were applied. The contact angle was established directly by use of a KRÃSS DSA10 goniometer or - building on digital images of droplets, an appropriate geometrical approach and tangent methods were applied. The study revealed that the droplet contact angle of nanofluids depends on surface roughness, type of substrate, material of nanoparticles, and concentration of nanoparticles.
Keywords
Related Topics
Physical Sciences and Engineering
Chemical Engineering
Fluid Flow and Transfer Processes
Authors
Janusz T. CieÅliÅski, Katarzyna A. Krygier,