Article ID | Journal | Published Year | Pages | File Type |
---|---|---|---|---|
7052830 | International Communications in Heat and Mass Transfer | 2018 | 8 Pages |
Abstract
Mixed convection heat transfer from a heated circular cylinder asymmetrically placed in a horizontal channel was studied for incompressible Newtonian fluid. A systematic investigation using two-dimensional numerical simulation (Ansys Fluent) was performed for the following control parameters: Reynolds number Reâ¯=â¯50, 100, 150, Richardson number Riâ¯=â¯0, 1, 2, blockage ratio βâ¯=â¯0.2, 0.3, 0.4, gap ratio γâ¯=â¯0.25, 0.5, 1 and Prandtl number of air Prâ¯=â¯0.7. Upon changing these parameters, steady and time periodic regimes were identified. The strongest influence on heat transfer (average Nusselt number) was identified when changing the Reynolds number (a 94% increase between the minimum and maximum Re investigated, with other parameters held constant), followed by Richardson number (+18%) and blockage ratio (+16%); the effect of asymmetric placement (γ) was almost negligible (+1%). The time-mean of the drag coefficient was most influenced by blockage ratio (a 150% increase), followed by Richardson number (+91%), gap ratio (+19%), and Re (+10%).
Keywords
Related Topics
Physical Sciences and Engineering
Chemical Engineering
Fluid Flow and Transfer Processes
Authors
Amit Dhiman, Rishabh Gupta, László Baranyi,