Article ID | Journal | Published Year | Pages | File Type |
---|---|---|---|---|
7054862 | International Journal of Heat and Mass Transfer | 2018 | 16 Pages |
Abstract
We perform numerical simulations to study effects of alternating current (AC) frequency on thermal stress evolution during the Joule heating process in a 48-rod Siemens reactor. The characteristics of temperature, current density, and stress distributions within the rods located in different rings are analyzed first. A Joule heating model using AC is then proposed for flexible power adjustment. The voltage-current curves are obtained from analysis of rod radius, location, and skin depth, as well as the properties of the polysilicon. The results indicate that, during the Joule heating process, large stresses typically occur in the central regions of the silicon rods. The highest stress occurs at the center of the silicon rods located in the outer ring when a standard power frequency of 50â¯Hz is utilized. The results further indicate that von Mises stress significantly decreases as AC frequency increases. Additionally, we propose a novel Joule heating method that is useful for producing larger high-purity polycrystalline silicon rods by considering both low frequency and high frequency power. Based on an analysis of energy consumption during the Joule heating process, we recommend optimized power supplies for the 48-rod Siemens reactor.
Related Topics
Physical Sciences and Engineering
Chemical Engineering
Fluid Flow and Transfer Processes
Authors
Zhifeng Nie, Palghat A. Ramachandran, Yanqing Hou,