Article ID Journal Published Year Pages File Type
7056280 International Journal of Heat and Mass Transfer 2015 9 Pages PDF
Abstract
The steady-state characteristics of natural circulation loop (NCL) were investigated by a homogenous model with SINDA/FLUINT. Under different condition of heat loads, cooling temperature, friction of the loop and driving force etc., the NCL can be operated in different operation modes, such as all two-phase, all liquid, two-phase-liquid, or gas-two-phase-liquid etc. A pair of non-dimensional parameters, namely ηp and ηl, is proposed to characterize the operation modes of the NCL. ηp stands for the relative size of the driving force, while ηl stands for the non-dimensional length of condensation, which describes the capability of the condenser. Three structures of NCL with water and totally over 1000 cases were run. The result was summarized in the ηp-ηl maps. They present the boundaries that all of four different operation modes in the map, which means the two non-dimensional parameters ηp and ηl can be used for scaling the operation modes.
Related Topics
Physical Sciences and Engineering Chemical Engineering Fluid Flow and Transfer Processes
Authors
, , , ,