Article ID | Journal | Published Year | Pages | File Type |
---|---|---|---|---|
7058299 | International Journal of Heat and Mass Transfer | 2013 | 4 Pages |
Abstract
The optimal working fluid inventory of a prototype of a cryogenic loop heat pipe (CLHP) is studied in this paper. The CLHP prototype operates within a temperature range of 77-126Â K with nitrogen as the working fluid. The possible fluid inventory range is calculated based on analysis of phase distribution of vapor and liquid within the loop in a normal operation mode. Furthermore, a series of experiments are carried out with various filling pressures of the gaseous nitrogen at room temperature for validation of the fluid inventory range and identification of the optimal fluid inventory. The experimental results are compared with the calculation results, and the effect of different filling pressure on the performance of the CLHP is analyzed.
Keywords
Related Topics
Physical Sciences and Engineering
Chemical Engineering
Fluid Flow and Transfer Processes
Authors
Tao Yan, Ya-nan Zhao, Jingtao Liang, Fulong Liu,