Article ID | Journal | Published Year | Pages | File Type |
---|---|---|---|---|
7060616 | International Journal of Thermal Sciences | 2018 | 9 Pages |
Abstract
A high voltage can achieve the electrical breakdown of an oil shale, and a heating channel is formed inside the oil shale. Subsequently, the industrial electrical frequency is used to heat the oil shale with the produced plasma and the inner surface of the conductive carbonization channel, which then causes the oil shale to crack. A three-dimensional coupling model of an oil shale is established by the finite element analysis software, and the temperature field distribution of a high-voltage breakdown of an oil shale is obtained by numerical calculations. The reliability of the numerical simulation is verified by laboratory tests. When the voltage is 1000â¯V, the breakdown current in the oil shale is 22 A. After heating for 6â¯min, the heating channel temperature of the oil shale reaches 643â¯Â°C. Within a 25-mm heating channel length, the temperature reaches 347â¯Â°C, which meets the demand of oil shale pyrolysis. Combined with the numerical simulations and experimental results, the high-voltage industrial-frequency pyrolysis oil shale has high heating efficiency and high energy utilization efficiency. Thermoelectric coupling analysis is an effective way to study the high-voltage-breakdown industrial-frequency pyrolysis of oil shale.
Related Topics
Physical Sciences and Engineering
Chemical Engineering
Fluid Flow and Transfer Processes
Authors
Sun Youhong, Zhao Shuai, Li Qiang, Liu Shichang, Han Jing,