Article ID | Journal | Published Year | Pages | File Type |
---|---|---|---|---|
7120860 | Measurement | 2018 | 10 Pages |
Abstract
The effect of the modified multiplier resistor on the measurement accuracy of ac voltages higher than 50â¯V is studied and evaluated in this paper. Modification in construction is made in the multiplier design which used for higher voltages. Ten resistors are radially connected in series and mounted on a high insulation PCB board instead of using one resistor which has higher power rating and thickness. The introduced multipliers values which are established at the National Institute of Standards (NIS), Egypt are 10â¯kΩ, 20â¯kΩ and 40â¯kΩ for voltages 50â¯V, 100â¯V, and 200â¯V respectively. The high voltage modified multipliers are joined with single junction thermo-elements to produce the modified thermal voltage converters (TVCs). The modified TVCs are calibrated against other standard TVCs at different frequencies 20â¯Hz, 55â¯Hz, 1â¯kHz, 10â¯kHz, and 100â¯kHz. The ac-dc transfer differences of the modified TVCs are compared with the traditional TVCs to evaluate its performance. They introduce lower ac-dc differences than the traditional ones specifically at higher voltages and frequencies. The modified TVCs performance is also evaluated by comparing their measurement accuracy and precision at range 100â¯V with the traditional TVCs.
Keywords
Related Topics
Physical Sciences and Engineering
Engineering
Control and Systems Engineering
Authors
Rasha S.M. Ali,