Article ID Journal Published Year Pages File Type
7122844 Measurement 2016 14 Pages PDF
Abstract
Technological limitations in sensor manufacturing and unwanted magnetic fields will corrupt the measurements of three-axis magnetometers. An experiment with four different magnetic disturbance situations is designed, and the influence of hard-iron and soft-iron material is analyzed. The calibration method with magnetic disturbance parameters is proposed for calibration and magnetic disturbance compensation of three axis magnetometers. It is not necessary to compute pseudo-linear parameters, thus the integrated parameters are computed directly by solving nonlinear equations. To employ this method, a nonmagnetic rotation equipment, a CZM-3 proton magnetometer, a DM-050 three-axis magnetometer, two magnets and two steel tubes are used. Calibration performance is discussed in the four situations. Compared with several traditional calibration methods, experiment results show that the proposed method has better integrated compensation performance in all situations, and error is reduced by several orders of magnitude. After compensation, RMS error is reduced from 10797.962 nT to 15.309 nT when the big magnet and steel tube are deployed. It suggests an useful method for calibration and magnetic disturbance compensation of three-axis magnetometers.
Related Topics
Physical Sciences and Engineering Engineering Control and Systems Engineering
Authors
, , , , , ,