Article ID | Journal | Published Year | Pages | File Type |
---|---|---|---|---|
7122983 | Measurement | 2016 | 6 Pages |
Abstract
The reported work has been carried out in the direction of establishment of metrological traceability of capacitance up to 200Â MHz at CSIR-NPL. In this perspective, the set of seven coaxial reference air-lines (Type 900-LZ series) exhibiting capacitance values varying from 2Â pF to 20Â pF have been realized as a capacitance standard at high frequency (1Â MHz-200Â MHz). This is principally achieved with reference to the SI base units of the meter and the second. The standard value of capacitance of each of the reference air-line has been computed up to 1000Â MHz by employing transmission line theory. The reference capacitance value of each of these air-lines has also been measured at 1Â kHz which thereafter extrapolated up to 1000Â MHz using resonance technique. RF impedance analyzer has been calibrated up to 200Â MHz for capacitance using computed capacitance of reference air-lines as standard. The reported work will be helpful in establishing the calibration services for low value of capacitance standards in a frequency range from 1Â MHz to 200Â MHz at CSIR-NPL. The work will also bridge the gap between LF and RF impedance metrology.
Related Topics
Physical Sciences and Engineering
Engineering
Control and Systems Engineering
Authors
Satish Satish, Sachin Kumar, Babita Babita, Thomas John, A.K. Saxena,