Article ID Journal Published Year Pages File Type
7133462 Sensors and Actuators A: Physical 2018 30 Pages PDF
Abstract
This paper presents a novel read-out approach both for eliminating parasitic feedthrough current and for enhancing the quality-factor (Q) of the resonating system at the same time. A new resonance characterization method based on sensing second harmonic component of the resonators was developed. Utilizing this method, the feedthrough current was eliminated and the signal-to-background ratio was increased from 0.9 dB to 35.5 dB. Furthermore, the Q of the resonating system was improved by 65% experimentally. It was shown that this method is suitable for eliminating both capacitive and resistive feedthrough current without using complex MEMS designs and interface electronics.
Keywords
Related Topics
Physical Sciences and Engineering Chemistry Electrochemistry
Authors
, , , , ,