Article ID Journal Published Year Pages File Type
7133869 Sensors and Actuators A: Physical 2018 18 Pages PDF
Abstract
The major failing of robotic and prosthetic grippers in mimicking the dexterity of the human hand is thought to be a lack of adequate tactile sensing which provides feedback for grip control. The majority of existing tactile sensors focus on determining the contact forces; however, other tactile parameters, such as friction and the occurrence of incipient slip, are equally important for dexterous manipulation, particularly in unstructured environments. In this work, a design is presented for a grip security sensor - the PapillArray - which consists of an array of silicone pillars with different uncompressed heights. When the sensor is compressed, the tallest pillars in the centre are under greater normal stress and thus able to generate a greater friction force; this encourages the shorter outer pillars to slip first when a tangential force is applied. The incipient slip (as pillars slip independently) can be detected by measuring the deflection of the individual pillars, and continuous force/torque measurement is not strictly required. Each incipient slip event acts as a warning that the grip/normal force should be increased. A simple mathematical description of the principle of operation of one embodiment of the PapillArray with a single taller central pillar surrounded by eight shorter outer pillars (of equal height) is offered. A prototype of this embodiment is also presented and tested under different normal forces and frictional conditions. The deflection of the central pillar and a single outer pillar are determined by video recording and subsequent point-tracking methods. The outer pillar was observed to slip at a lower tangential force than the central pillar. From the simplified model, a prediction of the tangential-to-normal force ratio at the moment of slip of the central pillar was made. The R2 value for a line of best fit for the predicted and measured ratio was 0.986 indicating an excellent fit, and the gradient of the line was 0.935, indicating that the predicted value is a slight underestimate of the coefficient of friction; this could be due to the assumption of unbending pillars. Both with and without continuous force monitoring, the PapillArray sensor can be used to improve dexterous manipulation in robotic and prosthetic grippers. This paper provides a proof-of-concept for this sensing approach; future papers will deal with the problem of instrumenting the pillar deflection by other means.
Related Topics
Physical Sciences and Engineering Chemistry Electrochemistry
Authors
, , , , , ,