Article ID Journal Published Year Pages File Type
7135326 Sensors and Actuators A: Physical 2016 12 Pages PDF
Abstract
Carbon Capture and Storage is a technology to reduce greenhouse gas emissions. CO2 leak from high pressure CO2 transportation pipelines can pose a significant threat to the safety and health of the people living in the vicinity of the pipelines. This paper presents a technique for the efficient localization of CO2 leakage in the transportation pipelines using acoustic emission method with low frequency and narrow band sensors. Experimental tests were carried out on a lab scale test rig releasing CO2 from a stainless steel pipe. Further, the characteristics of the acoustic emission signals are analyzed in both the time and the frequency domains. The impact of using the transverse wave speed and the longitudinal wave speed on the accuracy of the leak localization is investigated. Since the acoustic signals are expected to be attenuated and dispersed when propagating along the pipe, empirical mode decomposition, signal reconstruction and a data fusion method are employed in order to extract high quality data for accurate localization of the leak source. It is demonstrated that a localization error of approximately 5% is achievable with the proposed detecting system.
Related Topics
Physical Sciences and Engineering Chemistry Electrochemistry
Authors
, , , , ,