Abstract
The purpose of this study is to determine the optimal operating conditions and performance for the design of ORC based biomass compact CHP for 2â¯kW of electric, 25â¯kW of thermal power productions and 60â¯Â°C warm water supply. Eight organic working fluids were selected based on thermo-physical properties and related environmental regulations: cyclopentane, isopentane, n-pentane, diethyl ether, HFO-1233zd, HFC-245fa, HFE-7000 and HFE-7100. The selected organic fluids were classified into three groups considering latent heat and boiling point. The group A fluids contained cyclopentane, isopentane, n-pentane and diethyl ether. The group B fluids contained HFO-1233zd and HFC-245fa. The group C fluids contained HFE-7000 and HFE-7100. A micro CHP system composed of a biomass boiler (200â¯Â°C heat source), an ORC power cycle and a cooling water line (20â¯Â°C cooling water supply) was modeled in four variants depending on whether post-heater and IHE were applied or not. The subcritical ORC cycle and saturated vapor state at the inlet of the expander were considered for the analysis. As a result of thermodynamic analyses and optimizations, the group A fluids have the best CHP performance because of the greatest latent heat amount. The systems using the group A fluids have the lowest mass flow rates from 0.053â¯kg/s to 0.081â¯kg/s, the lowest required heat supplies from 31.64â¯kW to 34.61â¯kW, the highest ORC efficiencies from 5.95% to 7.29% and the CHP efficiencies from 71.83% to 72.32%. The group B fluids have the mass flow rates from 0.157 to 0.215â¯kg/s, the highest required heat supplies from 36.98â¯kW to 46.41â¯kW, the lowest system efficiencies from 4.59% to 6.05% and the highest CHP efficiencies from 72.05% to 73.41%. The group C fluids have the highest mass flow rates from 0.213â¯kg/s to 0.230â¯kg/s, the required heat supplies from 32.30â¯kW to 40.54â¯kW, the system efficiencies from 5.07% to 6.36% and the lowest CHP efficiencies from 71.31% to 72.33%. In addition, ORC systems using the group A or group C fluids can operate at low pressure and can meet system requirements with low cooling water mass flow rate because of the high boiling points. For the group A fluids, both post-heater and IHE are very effective for the system, and the system using the group B fluids can highly improve the system through the application of the post-heater. For the group C fluids, application of the IHE significantly improves system performance.
Related Topics
Physical Sciences and Engineering
Energy
Energy (General)
Authors
Yongtae Jang, Jaeseon Lee,