Article ID Journal Published Year Pages File Type
7165511 Energy Conversion and Management 2014 10 Pages PDF
Abstract
Energy, in conjunction with exergy, analysis of a waste heat driven Organic Rankine Cycle (ORC) is performed. Using actual plant data, performance of the cycle and pinpoint sites of primary exergy destruction are assessed. Furthermore, variations of energy and exergy efficiencies of the system with evaporator/condenser pressures, superheating and subcooling are illustrated. It is observed from the analysis that, the energy and exergy efficiencies of the system are 10.2%; 48.5% and 8.8%; 42.2%, respectively, for two different actual cases. Exergy destruction of subcomponents is also quantified. The components with greater exergy destructions to lower one can be listed as evaporator, turbine, condenser and pump. Evaporation pressure has significant effect on both energy and exergy efficiencies. Pinch-point analysis is, also performed to determine effects of heat exchange process, in the evaporator, on the net power production.
Related Topics
Physical Sciences and Engineering Energy Energy (General)
Authors
,