Article ID Journal Published Year Pages File Type
7166023 Energy Conversion and Management 2014 8 Pages PDF
Abstract
An experimental investigation of ice formation on cold vertical banks of horizontal tubes subjected to falling-film- jet mode- is conducted. In the charging process, a set of internally cooled vertical banks of horizontal tubes of brine is subjected to a falling film of water. The formed ice is periodically observed, photographed and measured in falling-film jet mode at specific internal coolant (ethylene-glycol solution) flow rates and temperatures. In the discharge process, the same solution is heated and used internally to release ice. Different thicknesses of the released ice are observed and measured. The maximum quantity of released ice is obtained and the optimum ice formation is determined. The results indicate that the ice formation and the solid ice released are controlled by the thermal resistance of the ice, time and pitch between tubes. The maximum gained ice has a thickness that is approximately equal to half of the tube spacing between the tubes utilized, which is formed in approximately 45 min and released in 12.5 min. The variation in heating solution temperature has a slight effect on the gained ice and discharging time.
Related Topics
Physical Sciences and Engineering Energy Energy (General)
Authors
, ,