Article ID Journal Published Year Pages File Type
7171132 International Journal of Adhesion and Adhesives 2014 47 Pages PDF
Abstract
We present characterisation interface tests results obtained by push-out tests adapted to a Steel-concrete bonded connection. The sizes of the concrete slabs and areas of the bonding zone are the primary studied parameters. It is shown that the behaviour observed during the push-out tests strongly depends on these parameters. Additionally, the measurements are compared to numerical results obtained from 3D FE models accounting for the non-linear behaviour of the constitutive materials. In particular, the numerical results confirm that the shear stress in the concrete slabs along the bonding joint and near the interface is not uniform and varies with the level of the applied load. Moreover, the shear stress may be accompanied by a strong compression stress perpendicular to the interface, which is mainly due to the possible friction between the bottom face of the concrete slabs and the steel rigid plate of the hydraulic press. This stress induces a favourable double state of stress in the bonding joint and a high failure load. Therefore, these tests and numerical results show that the state of stress in a push-out test is complex, varies with the load and seems to be most likely not representative of the state of stress in a flexural member. Consequently, the push-out test can be used as a way of characterising a Steel-concrete bonding connection that may be useful in comparing different adhesives or bonding processes; however, this test should be used very carefully for beam designs.
Related Topics
Physical Sciences and Engineering Engineering Mechanical Engineering
Authors
, , ,