Abstract
Test results from the literature for Glare 4B-3/2-0.3 have been replicated using the aforementioned methodology. It is shown that it can accurately predict the number of cycles to crack initiation, although the S-N data that is used for the predictions dictates the obtained accuracy. The closer the stress cycle value of the S-N data is to the value of the case analysed, the higher the accuracy obtained. Such a trend was not observed for the stress concentration factor of the S-N curves used, although a choice for S-N data with a different stress concentration factor can cause a significant change in precision. The method is also shown to work for several other fibre metal laminates.
Related Topics
Physical Sciences and Engineering
Engineering
Mechanical Engineering
Authors
S.W.F. Spronk, I. Åen, R.C. Alderliesten,