Article ID Journal Published Year Pages File Type
7180639 Precision Engineering 2016 18 Pages PDF
Abstract
To ensure the metrology traceability chain to the SI metre definition, the calibration of the MFB is carried out using an accurate traceable coordinate measuring machine (CMM) when applying the reversal technique. The established procedure for the identification of the geometric errors was applied on a 5-axis MT, leading to the identification of the apparent 21 geometric errors of the 3 linear axes. To achieve with this purpose, the number of required positions of the MFB was optimized and reduced to only 6 positions, while using both rotary axes. The collection of raw data for each measurement was performed thanks to an accurate touch probe, linear encoders of the MT, as well as a developed interface that is independent of the industrial computer numerical control (CNC). Furthermore, the sensitivity of the geometric errors on the linear axes position is highlighted.
Related Topics
Physical Sciences and Engineering Engineering Industrial and Manufacturing Engineering
Authors
, , , ,