Article ID Journal Published Year Pages File Type
7206935 Journal of the Mechanical Behavior of Biomedical Materials 2018 35 Pages PDF
Abstract
The mechanical behaviour of porous lattice materials for potential orthopaedic applications was investigated at a fine scale by means of digital image correlation (DIC). Specimens with cubic, body cubic-centered reinforced (BCCZ), and diamond mesostructures were tested in quasi-static compression up to failure. Images were continuously recorded by an imaging setup and processed by a custom DIC program, OpenDIC. The resulting strain maps were analyzed in both spatial and temporal scales, displaying the onset and evolution of strain heterogeneities. The three geometries show different failure modes, i.e. collective buckling of an entire row for cubic, diagonal shearing band for BCCZ, and generalized crushing for diamond. The strain maps correlate well with these patterns. Most importantly, they show early strain localization below the macroscopic elastic limit. After failure, a phenomenon of strain release was witnessed and evaluated in the parts of the specimen that do not fracture. In the cubic geometry, the vertical struts sustain most of the deformation. Further analysis shows that the rows of vertical struts have similar, yet scattered, evolutions until failure. Interestingly, the row that leads to specimen failure is not necessarily the first one to deform. In addition to these experimental results, the uncertainties of the method were thoroughly assessed by means of calibration procedures.
Related Topics
Physical Sciences and Engineering Engineering Biomedical Engineering