Article ID Journal Published Year Pages File Type
7209297 Journal of the Mechanical Behavior of Biomedical Materials 2013 14 Pages PDF
Abstract
Rotary bending curves for Ni50.8Ti49.2 bright wire with Af=2 °C tested at −25 °C, 23 °C, and 60 °C, with corresponding ∆T (=T−Af) values of −27, 21, and 58 °C, respectively. Data at ≥107 cycles did not fracture and are considered run-out conditions. Trend lines from regression analyses are drawn to delineate strain amplitude regions for these three sets of data. Note that for conditions of pseudoelasticity (stress-induced Austenite to B19' Martensite) there are four distinct regions in the curves, whereas there are only two regions for the data from the lowest test temperature (R-Phase). These regions are correlated to differences in strain accommodation mechanisms for the phases. 90
Related Topics
Physical Sciences and Engineering Engineering Biomedical Engineering