Article ID | Journal | Published Year | Pages | File Type |
---|---|---|---|---|
7209501 | Journal of the Mechanical Behavior of Biomedical Materials | 2011 | 9 Pages |
Abstract
⺠The use of Ti40Zr10Cu38Pd12 metallic glass for orthopedic implants is investigated. ⺠The changes in microstructure, mechanical and corrosion properties of this alloy during heat-treatments are studied. ⺠The hardness, wear resistance and corrosion resistance improve during partial or full crystallization of the glassy alloy.
Related Topics
Physical Sciences and Engineering
Engineering
Biomedical Engineering
Authors
J. Fornell, N. Van Steenberge, A. Varea, E. Rossinyol, E. Pellicer, S. Suriñach, M.D. Baró, J. Sort,