Article ID | Journal | Published Year | Pages | File Type |
---|---|---|---|---|
7211056 | Alexandria Engineering Journal | 2017 | 13 Pages |
Abstract
The main objective of this research was to evaluate and enhance dynamic performance for a vertical pumping unit. The original electric motor of the pump unit had been replaced by another one different in design and weights. Vibration has been increased greatly after installing the new motor. Consequently, it is necessary to estimate the change in the vibration characteristics owing to the difference in the boundary conditions of the new motor. Measured vibration levels and frequency analysis were dangerous at 1Ã due to resonance problem. Finite Element Analysis was used to model the motor structure in order to find its natural frequencies and mode shapes. The results confirm that the third natural frequency is very close to 1Ã operating speed with deviation about 1%. To solve the resonance problem, it was recommended to increase the structure stiffness. The results after modifications confirmed that the overall vibration level decreases by 89%.
Keywords
Related Topics
Physical Sciences and Engineering
Engineering
Engineering (General)
Authors
Dalia M. El-Gazzar,